Taurochenodeoxycholic Acid-d4 MaxSpec® Standard
本产品不向个人销售,仅用作科学研究,不用于任何人体实验及非科研性质的动物实验。
Taurochenodeoxycholic Acid-d4 MaxSpec® Standard图片
CAS NO:1207294-24-3
包装:100µg
市场价:2253元

产品介绍
A quantitative analytical standard guaranteed to meet MaxSpec®identity, purity, stability, and concentration specifications
Cas No.1207294-24-3
Canonical SMILESC[C@H](CCC(NCCS([O-])(=O)=O)=O)[C@@]1([H])CC[C@@]2([H])[C@]3([H])[C@H](O)C[C@]4([H])C([2H])([2H])[C@H](O)C([2H])([2H])C[C@]4(C)[C@@]3([H])CC[C@@]21C
分子式C26H41D4NO6S
分子量503.7
储存条件-20°C
General tipsFor obtaining a higher solubility , please warm the tube at 37 ℃ and shake it in the ultrasonic bath for a while.
Shipping ConditionEvaluation sample solution : ship with blue ice
All other available size: ship with RT , or blue ice upon request
产品描述

Taurochenodeoxycholic acid-d4(TCDCA-d4) is intended for use as an internal standard for the quantification of TCDCA by GC- or LC-MS. TCDCA is a taurine-conjugated form of the primary bile acid chenodeoxycholic acid .1Serum levels of TCDCA increase approximately 5-fold within two hours and begin to decrease within four hours during an oral lipid tolerance test in humans.2Serum levels of TCDCA are increased in patients with liver cirrhosis and may serve as a marker of disease progression.3

TCDCA-d4MaxSpec®standard is a quantitative grade standard of TCDCA-d4that has been prepared specifically for mass spectrometry and related applications where quantitative reproducibility is required. The solution has been prepared gravimetrically and is supplied in a deactivated glass ampule sealed under argon. The concentration was verified by comparison to an independently prepared calibration standard. The verified concentration is provided on the certificate of analysis. This TCDCA-d4MaxSpec®standard is guaranteed to meet identity, purity, stability, and concentration specifications and is provided with a batch-specific certificate of analysis. Ongoing stability testing is performed to ensure the concentration remains accurate throughout the shelf life of the product.Note: The amount of solution added to the vial is in excess of the listed amount. Therefore, it is necessary to accurately measure volumes for preparation of calibration standards. Follow recommended storage and handling conditions to maintain product quality.

1.Hoffman, A.F.The continuing importance of bile acids in liver and intestinal diseaseArch. Intern. Med.159(22)2647-2658(1999) 2.Schmid, A., Neumann, H., Karrasch, T., et al.Bile acid metabolome after an oral lipid tolerance test by liquid chromatography-tandem mass spectrometry (LC-MS/MS)PLoS One11(2)e0148869(2016) 3.Wang, X., Xie, G., Zhao, A., et al.Serum bile acids are associated with pathological progression of hepatitis B-induced cirrhosisJ. Proteome Res.15(4)1126-1134(2016)