您好,欢迎来到试剂仪器网! [登录] [免费注册]
试剂仪器网
位置:首页 > 产品库 > Taurolithocholic Acid-d4 MaxSpec? Standard
立即咨询
咨询类型:
     
*姓名:
*电话:
*单位:
Email:
*留言内容:
请详细说明您的需求。
*验证码:
 
Taurolithocholic Acid-d4 MaxSpec? Standard
本产品不向个人销售,仅用作科学研究,不用于任何人体实验及非科研性质的动物实验。
Taurolithocholic Acid-d4 MaxSpec? Standard图片
包装:100ug
规格:98%
市场价:2948元
分子量:487.7

产品介绍
A quantitative analytical standard guaranteed to meet MaxSpec? identity, purity, stability, and concentration specifications
货号:ajcx24128
CAS:2410279-96-6
分子式:C26H41D4NO5S
分子量:487.7
溶解度:
纯度:98%
存储:Store at -20°C
库存:现货

Background:

Taurolithocholic acid-d4(TLCA-d4) is intended for use as an internal standard for the quantification of TLCA by GC- or LC-MS. TLCA is a taurine-conjugated form of the secondary bile acid lithocholic acid .1TLCA (75 μM) increases caspase-3 and -7 activity in Hep3B cells transfected with sodium taurocholate cotransporting peptide (NTCP), but not nontransfected Hep3B cells.2It has been used to induce cholestasis inex vivoandin vivoanimal models of hepatocellular cholestasis.3,4Serum levels of TLCA increase approximately 5-fold within two hours during an oral lipid tolerance test in humans.1
TLCA-d4MaxSpec?standard is a quantitative grade standard of TLCA-d4that has been prepared specifically for mass spectrometry and related applications where quantitative reproducibility is required. The solution has been prepared gravimetrically and is supplied in a deactivated glass ampule sealed under argon. The concentration was verified by comparison to an independently prepared calibration standard. The verified concentration is provided on the certificate of analysis. This TLCA-d4MaxSpec?standard is guaranteed to meet identity, purity, stability, and concentration specifications and is provided with a batch-specific certificate of analysis. Ongoing stability testing is performed to ensure the concentration remains accurate throughout the shelf life of the product.Note: The amount of solution added to the vial is in excess of the listed amount. Therefore, it is necessary to accurately measure volumes for preparation of calibration standards. Follow recommended storage and handling conditions to maintain product quality.


1.Schmid, A., Neumann, H., Karrasch, T., et al.Bile acid metabolome after an oral lipid tolerance test by liquid chromatography-tandem mass spectrometry (LC-MS/MS)PLoS One11(2)e0148869(2016) 2.Rust, C., Wild, N., Bernt, C., et al.Bile acid-induced apoptosis in hepatocytes is caspase-6-dependentJ. Biol. Chem.284(5)2908-2916(2009) 3.Denk, G.U., Maitz, S., Wimmer, R., et al.Conjugation is essential for the anticholestatic effect of NorUrsodeoxycholic acid in taurolithocholic acid-induced cholestasis in rat liverHepatology52(5)1758-1768(2010) 4.Javitt, N.B.Cholestasis in rats induced by taurolithocholateNature210(5042)1262-1263(1966)