CAY10603
本产品不向个人销售,仅用作科学研究,不用于任何人体实验及非科研性质的动物实验。
CAY10603图片
CAS NO:1045792-66-2
规格:≥98%
包装与价格:
包装价格(元)
5mg电议
10mg电议
25mg电议
50mg电议
100mg电议

产品介绍
理化性质和储存条件
Molecular Weight (MW)446.5
FormulaC22H30N4O6
CAS No.1045792-66-2
Storage-20℃ for 3 years in powder form
-80℃ for 2 years in solvent
Solubility (In vitro)DMSO: 89 mg/mL (199.3 mM)
Water: <1 mg/mL
Ethanol: 5 mg/mL (11.2 mM)
Solubility (In vivo)5% DMSO+50% PEG 300+ddH2O: 9 mg/mL
Synonyms

CAY-10603; CAY10603; CAY 10603

Chemical Name: tert-butyl (4-(3-((7-(hydroxyamino)-7-oxoheptyl)carbamoyl)isoxazol-5-yl)phenyl)carbamate

SMILES Code: O=C(OC(C)(C)C)NC1=CC=C(C2=CC(C(NCCCCCCC(NO)=O)=O)=NO2)C=C1

实验参考方法
In Vitro

In vitro activity: CAY10603, via inhibition of HDAC6, shows potent antiproliferative activity against pancreatic cancer cell lines with IC50 of<1 μM, which can be used as a new molecular probe in exploring HDAC biology


Kinase Assay: Purified HDACs are incubated with 1 mM carboxyfluorescein (FAM)-labeled acetylated peptide substrate and test compound for 17 h at 25 °C in HDAC assay buffer containing 100 mM HEPES (pH 7.5), 25 mM KCl, 0.1% BSA, and 0.01% Triton X-100. Reactions are terminated by the addition of buffer containing 0.078% SDS for a final SDS concentration of 0.05%. Substrate and product are separated electrophoretically using a Caliper LabChip 3000 system with blue laser excitation and green fluorescence detection (CCD2). The fluorescence intensity in the substrate and product peaks is determined using the Well Analyzer software on the Caliper system. The reactions are performed in duplicate for each sample. IC50 values are automatically calculated using the IDBS XLFit version 4.2.1 plug-in for Microsoft Excel and the XLFit 4-Parameter Logistic Model: ((A+((B_A)/1+((C/x)D)))), in which x is compound concentration, A and B are respectively the estimated minimum and maximum of percent inhibition, C is the inflection point, and D is the Hill slope of the sigmoidal curve. The standard errors of the IC50 values are automatically calculated using the IDBS XLFit version 4.2.1 plug-in for Microsoft Excel and the formula xf4_FitResultStdError.


Cell Assay: The pancreatic cancer cell lines BxPc-3, HupT3, Mia Paca-2, Panc 04.03, and SU 86.86 are grown in medium (DMEM or RPMI) containing 10% fetal calf serum and l-glutamine. Pancreatic cancer cells are plated out in duplicate into 6 wells of a 96-well microtiter plate. Four hours post plating, individual wells are treated with diluent (DMSO) or varying concentrations of SAHA or the indicated HDACIs from a concentration of 1 nM to 50 mM. Cytotoxicity is measured at time “0”, and 72 h post treatment using the colorimetric MTT assay according to the manufacturer’s suggestions. The IC50 values are calculated using XLfit.

In VivoNA
Animal modelNA
Formulation & DosageNA
References

J Med Chem. 2008 Aug 14;51(15):4370-3.